9-30

E DV-90-IM

9

PLC Link

9-5 Settings

Settings for the SYSMAC Series

„ Settings of the DV-90

„ C120-LK201-V1

* The data length, parity, and stop bit are fixed to 7, even, and 2, respectively.

„ C200H-LK201-V1

PORT2 connecting device

PLC Link

PLC type

SYSMAC

PLC unit ID

0

Baud rate

9600 bits/s

Data length

7 bits

Parity

Even

Stop bit length

2 bits

Note

Set the data length to “8 bits” when the code reader to be connected to the DV-90 is a
2D code reader that also reads double-byte codes.
Set the data length to “8 bits” in the PLC setting as well.

Unit number

0

Transmission speed

*

9600 bits/s

1:1/1: N Handshake

1: N procedure

Level setting

Valid for level 1, 2, and 3

CTS selection

0 V

Synchronization selection

Internal synchronization

Unit number

00

Transmission speed

9600 bits/s

Command level

Valid for level 1, 2, and 3

Data length

7 bits

Parity

Even

Stopbit length

2 bits

1:1/1: N Handshake

1: N Handshake

5-V supply

None