Settings for the sysmac series, Settings for the sysmac series -30 – KEYENCE DV-90 User Manual
Page 230
9-30
E DV-90-IM
9
PLC Link
9-5 Settings
Settings for the SYSMAC Series
Settings of the DV-90
C120-LK201-V1
* The data length, parity, and stop bit are fixed to 7, even, and 2, respectively.
C200H-LK201-V1
PORT2 connecting device
PLC Link
PLC type
SYSMAC
PLC unit ID
0
Baud rate
9600 bits/s
Data length
7 bits
Parity
Even
Stop bit length
2 bits
Note
Set the data length to “8 bits” when the code reader to be connected to the DV-90 is a
2D code reader that also reads double-byte codes.
Set the data length to “8 bits” in the PLC setting as well.
Unit number
0
Transmission speed
*
9600 bits/s
1:1/1: N Handshake
1: N procedure
Level setting
Valid for level 1, 2, and 3
CTS selection
0 V
Synchronization selection
Internal synchronization
Unit number
00
Transmission speed
9600 bits/s
Command level
Valid for level 1, 2, and 3
Data length
7 bits
Parity
Even
Stopbit length
2 bits
1:1/1: N Handshake
1: N Handshake
5-V supply
None