KEYENCE DV-90 User Manual

Page 72

Advertising
background image

4-12

E DV-90-IM

4

Ba
si

c

Func

tions

2

Display the verification settings menu

Press the

or

key to place the cursor on

“2 Verify”.
Then, press the

key.

3

Display the interlock settings.

Press the

or

key to display the interlock

settings, then press the

key.

4

Specify the interlock function.

The displays are switched by pressing the

or

key.

• “OFF”

...The interlock function is not activated.

• “at Verify OK”

...Interlock is performed when Verify OK occurs.

• “at Verify NG”

...Interlock is performed when Verify NG occurs.

• “at Read Error”

...Interlock is performed when a read error occurs.

Press the

key to specify the function.

5

Exit the setting mode.

Press the

key twice.

„ Display of interlock state and cancellation

The sign shown below is displayed in the interlock
state.

The interlock state is cancelled by turning ON the

UNLOCK input or by pressing the

key. The dis-

play will be as shown below.

1 : B i t

P a r a l l e l O u t

0 1

0 : O F F

I n t e r l o c k

0 5

ESC

1 2 3 4 5 6 7 8 9 0

Flashing

( R e a d y t o R e a d )

4-2 Normal Verification