KEYENCE DV-90 User Manual

Page 195

Advertising
background image

8-17

8

E DV-90-IM

Ser

ia

l Comm

unicati

on

8-3 Command Communication Details

„ Settings relevant to PLC link

„ Settings relevant to I/O

Function

Sending command

Response

Notes

DM Address

Change

WRF0nn

OK

nn = 00 through 99 (unit:100)

Check

RDF0

nn

PLC Time Area

Change

WRF1n

OK

n = 0: OFF

1: ON

Check

RDF1

n

PLC Type

Change

WRF2n

OK

n = 0: KEYENCE KV

1: MELSEC

2: SYSMAC

Check

RDF2

n

PLC Unit ID

Change

WRF3nn

OK

nn = 00 through 31: PLC Unit ID

Check

RDF3

nn

Function

Sending command

Response

Notes

Input Type

Change

WRE0n

OK

n = 0: A contact (N.C.)

1: B contact (N.O.)

Check

RDE0

n

Out ON Time

Change

WRE1nnn

OK

nnn = 001 through 255 (unit: 10 ms)

Check

RDE1

nnn

Out Delay

Change

WRE2nnn

OK

nnn = 000 through 255 (unit: 1 ms)

Check

RDE2

nnn

REMOTE KEY

Change

WRE3n

OK

n = 0: none

1: PRESET key

2: ESC key

3: ENTER key

Check

RDE3

n

Preset Mode Status

Output

Change

WRE4n

OK

n = 0: OFF

1: ON

Check

RDE4

n

Active Record

Selection Notification

Change

WRE5n

OK

n = 0: OFF

1: ON

Check

RDE5

n

Advertising