Appendix-16, Control of the read trigger, Data read process – KEYENCE DV-90 User Manual
Page 252: Select active record
Advertising

Appendix-16
E DV-90-IM
App
endix
Control of the read trigger
Input 0000 controls the read trigger.
Data read process
• When the “Write Complete Confirmation Flag”
displays “1: Data Write Complete”, it starts pro-
cessing the written data. After the process is
completed, each flag is initialized.
* DM0010 is valid only in “Sequence processing”.
Select active record
Set the Active record number to 1 from Input 0001.
Set the Active record number to 2 from Input 0002.
@MOV
0002
#0000
DM0011
@MOV
&2
DM0012
@MOV
0001
#0000
DM0011
@MOV
&1
DM0012
0000
#0001
DM0006
0000
@MOV
@MOV
#0000
DM0006
25313
CMP
DM0009
#0001
Continue to the next page
MOV
25506
#0000
DM0009
MOV
#0001
DM0010
This processes
data programs
written in DM100
and later.
Advertising