6 3-point-b verification function, Point-b verification function, Setting the 3-point-b verification function – KEYENCE DV-90 User Manual

Page 88: Point-b verification function -28

Advertising
background image

4-28

E DV-90-IM

4

Ba
si

c

Func

tions

4-6

3-Point-B Verification Function

This function is used to compare and verify the master data in the order that the data is read, and the data is
counted as one group.
Verify OK is output each time the data is read.

3-Point-B Verification Function

The 3-point-B function verifies three registered master data items and three read data items. Regis-
ter the data “123”, “456”, and “789” first. When the read data is “123”, “456”, and “789” as well,
OK is output each time the data is read.
When the read data does not match the registered data, NG is output at the time the unmatched data
is read.

In 3-point-B verification, three data items of Master data 1 to 3 can be registered with one record
number. Each time the data is read, the verification is performed with Master data 1 to 3 in that
order. Then, the OK/NG result is output.

The operation flow for working with the 3-point-B verification function is as follows.

1 Setting the 3-point-B verification function
2 Presetting the master data
3 Working with the 3-point-B verification function

Setting the 3-Point-B Verification Function

1

Move to the setting mode.

Press the

key for one second. The display

enters the setting mode.

2

Displaying the basic settings menu.

Place the cursor on “Main” by pressing the

or

key. Then, press the

key.

1 2 3

1 2 3

4 5 6

4 5 6

7 8 9

7 8 9

Master data

Master

data 1

Master

data 2

Master

data 3

Verify

OK

First data reading

Second data reading

Third data reading

Verify

Verify

OK

OK

M a i n

2

V e r i f y

MENU

0 1

V e r i f y T y p e

0 : N o r m a l

Advertising