1 code reader setup basics, Code reader setup basics -2, Code reader setup basics – KEYENCE DV-90 User Manual

Page 26

Advertising
background image

2-2

2

Initial Setup

of the Cod

e

Reade

r

E DV-90-IM

2-1

Code Reader Setup Basics

This section describes the preparation flow before using the DV-90.

1

In the settings of the DV-90, select "CR1 Type" in "Main".

Specify the type according to the code reader to connect.

(Setting procedure)

(1) Press the

key for one second to enter the setting mode.

(2) Select “1 Main” and press the

key.

(3) Press the

key twice to display “03 CR1 Type”.

(4) Press the

key to display a cursor.

(5) Select “TypeA,B,C,D,E, or Others”, and press the

key.

(6) Press the

key twice to exit the setting mode.

2

Configure the settings of the connecting code reader as follows.

If the code reader is at default, no setting change is required.

<BL-1300/700/600/180 Series, HR-50RK/40RK/UC51, BL-210RK/N70RKE/N9R>

• Baud rate : 9600 bits/s

• Data length

: 7 bits

• Parity

: Even

• Stop bit length : 1 bit

• Header

: None

• Terminator

: CR or CR LF

• Communication protocol : No hand shaking

<TL-70R>

• Baud rate : 9600 bits/s

• Data length

: 8 bits

• Parity

: None

• Stop bit length : 1 bit

• Header

: None

• Terminator

: CR or CR LF

• Communication protocol : No hand shaking

<SR Series, HR-100>

• Baud rate : 115200 bits/s

• Data length

: 8 bits

• Parity

: Even

• Stop bit length : 1 bit

• Header

: None

• Terminator

: CR

• Communication protocol : No hand shaking

Code reader model name

Type

BL-1300/700/600/180 Series

Type A

HR-50RK/40RK/UC51

BL-N70RKE/N9R

Type B

TL-800, TL-70R

Type C

BL-210RK

Type D

SR Series, HR-100

Type E

Other code readers

Others

Reference

By specifying the code reader type, the settings such as the default values of the communi-
cation setting of the DV-90 and pin assignment of PORT1 are modified to suit the specified
code reader.

Note

If the setting cannot be changed on the code reader side, adjust the DV-90 settings for

“PORT1” in the setting mode of the DV-90. (

Refer to 6-8.)

If you are using the BL-1300/700/600/180 and the code reader setting cannot be checked, the

DV-90 can detect it automatically.
Refer to page 2-5 for automatic detection.

MENU