4-8

E DV-90-IM

4

Ba
si

c

Func

tions

4-2 Normal Verification

Working with the Normal Verification Function (Verification Mode)

Start reading the master data after it is registered.

1

The screen is displayed as shown on

the right.

2

Read the barcode.

The read data and the master data are verified.

z

When the read data matches the master

data (Verify OK)
• LED Display

...The matched record number is displayed.

• LCD display

...The code data or reference data is dis-
played.

• Parallel output (Out1-Out12)

...Outputs representing the matched record

(Preset 1-900) are turned ON. (

Refer to

4-11)

z

When the read data does not match the

master data (Verify NG)
• LED Display

...“999” (Verify NG) is displayed.

• LCD display

...The code data or reference data is dis-
played.

• Parallel output (Out1-Out12)

...Outputs representing “999” (NG and Verify
NG) are turned ON. ALL outputs are turned
OFF when Bit output format is selected

(default). (

Refer to 4-11)

OK

NG

12

11

10

9

8

7

6

5

4

3

2

1

ERR

( R e a d y t o R e a d )

OK

NG

12

11

10

9

8

7

6

5

4

TRG1

TRG2

3

2

1

ERR

1 2 3 4 5 6 7 8 9 0

OK

NG

12

11

10

9

8

7

6

5

4

TRG1

TRG2

3

2

1

ERR

1 1 2 2 3 3 4 4 5 5