KEYENCE DV-90 User Manual

Page 199

Advertising
background image

8-21

8

E DV-90-IM

Ser

ia

l Comm

unicati

on

8-3 Command Communication Details

When using Verify Normal, if you want to specify the number written above in Record number 2,
send the command as follows. Items other than the replacing character and the master data are in
the default settings.

MSET0

002

ENGIN-B

45678

s substitute the output number and the input limit because they are used in default settings.

The commands after “Designation 1” are omitted because they are used in the default settings.

When using Verify Active, if you want to initialize the data in Record number 10, send the com-
mand as follows. All the data can be initialized by omitting all commands after the “Output
number”.

MSET1

010

• Record number : 005
• Master data 1 : 12345Verify LimitForward Limit Start1

Limit Digits5

• Master data 2 : 6789Verify Limit Forward Limit Start10 Limit Digits4
• Master data 3 : AAAVerify Limit Reverse Limit Start1

Limit Digits3

When using the Verify 3points-A, if you want to change the data as written above, send the com-
mand as follows:

MSET3

005

12345

1

1

001

005

6789

1

1

010

004

AAA

2

001

003

Record

number

Output

number

Port

number

limitation

Replacing

characters

Master

data 1

Master 1

Designation

Master 1

Direction

Master 1

Limit

Start

Master 1

Limit

Digits

Master 1

Compare

Logic

001 001 ALL

ENGIN-A

12345

0

1

001

500

0

002 002 ALL

ENGIN-B

45678

0

1

001

500

0

HT

HT

HT

HT

HT

HT

Example

HT

Example

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

HT

Example

Advertising