363

ACCESS DENIED - ESCORT REQUIRED

A cardholder has presented a card requesting access to the area, but access was denied
because the cardholder is required to have an escort.

ACCESS DENIED - HOST COMMUNICATION LOSS

This event code only appears in the uploaded events file. Access was denied because the
SCP Device was offline for an access request that had to go to the Host. Example, Keypad
Masking requires host processing.

ACCESS DENIED - INVALID FLOOR NUMBER

Elevator Access was denied because the cardholder entered a floor number that the
cardholder is not authorized for.

ACCESS DENIED - INVALID ISSUE CODE

Access was denied because the Issue Code in the Cardholder Database is not what
encoded on the card.

ACCESS DENIED - LOCAL ANTI-PASSBACK VIOLATION

Access was denied locally in the ACU-2 because the cardholder has already used his/her
card to enter the security area without an intervening exit from the security area.

ACCESS DENIED - LOCAL SA RE-ENTRY TIMER VIOLATION

Access was denied locally in the ACU-2 because the cardholder requested access within
the Re-entry time as defined in the Security Area Configuration.

ACCESS DENIED - LOCAL TAILGATE VIOLATION

Access was denied locally in the ACU-2 because the cardholder has already used his/her
card to exit the security area without an intervening entrance to the security area.

ACCESS DENIED - SCP DEVICE ERROR

Elevator Access was denied because an SCP device was offline or deactivated.

ACCESS DENIED - SECURITY AREA NOT DEFINED

Access was denied because the security is not defined. You may get this event if the
Database has not been fully downloaded to the remote panel.

ACCESS DENIED - TAILGATE VIOLATION

Access was denied because the cardholder has already used his/her card to exit the
security area without an intervening entrance to the security area.