Base ARTM FPGA
ARTM-831X Installation and Use (6806800M76E)
120
8.2.7
Telecom Base Clock Receive Clocks
The MMC selects one of the clocks N8707_RCLK_P/M, CLK_REFCLK_1 or CLK_REFCLK_2. See
4.3.1.11 Telecom Reference Clock Selection.
8.2.8
Telecom Clocks
8.2.9
Status Sonet SFP
Table 8-7 Telecom Base Clock Receive Clocks
Signal Name
Type
Description
N8707_RCLK_P/M
I
Differential 10 GE receive clock RCLK
GE_RECCLK1
I
GE Receive clock 1
GE_RECCLK2
I
GE Receive clock 2
CLK_REFCLK_1
O
Receive clock REFCLK 1 to Zone 3
CLK_REFCLK_2
O
Receive clock REFCLK 2 to Zone 3
Table 8-8 Telecom Base Clock Receive Clocks
Signal Name
Type
Description
RTM_CLK_16MHZ
I
TDM 16MHz Clock from Zone 3
FPGA_CLK_T4_OUT
I
TDM T4 Clock from Zone3
CLK_T3_BITS
O
TDM T3 BITS Clock to Zone3
Table 8-9 Status Sonet SFP
Signal Name
Type
Description
FPGA_ACTIVE_RTM_OUT
I
Status Signal ADM
SFP_TXFAULT_1
I
Status TMUX 1 TXFAULT 1