3 artm-831x_ds3/oc3, Chapter 1, artm-831x_ds3/oc3, on, Introduction – Artesyn ARTM-831X Installation and Use (June 2014) User Manual
Page 31

Introduction
ARTM-831X Installation and Use (6806800M76E)
31
TSI-Expander unit:
–
Reference Clock Selector and Alarm signaling (LOS) for four E1/T1 Framer (channel 17
to 48)
1.2.3
ARTM-831X_DS3/OC3
Expansion PCB
16 E1/T1 I/O ports via one 68p VHDCI connector
–
Patch panel feed only, no line protection
–
Supports redundancy Y-connection at the patch panel (Lmax.= 1.8m)
Up to 24x DS3 or 8x OC3 or 2x OC12 TDM/SDH/Sonet interface
–
DS3 via two VHDCI connector for patch panel feed only, no line protection
–
Supports DS3 redundancy Y-connection at the patch panel
–
OC3/OC12 via SFP
Healthy signaling and Active/Standby switchover for 2 ARTM's
Locate and type-detect function for patch panel connection via IPMC
TSI unit:
–
64k TDM channels interchange management
–
TSIP2SerDes conversion for front board communication
–
PCIe x1 host interface & local bus for path overhead management
–
Sideband signal interface
–
HMVIP interface to E1/T1 Framer devices
–
SBI interface to SONET/SDH/DS3 Framer devices
–
Reference Clock Selector and Alarm signaling (LOS) for two E1/T1 Framer (channel 1 to
16) and for two SONET/SDH/DS3 Framer