9.5.2.5.1 Gr8 Initialization Register
Address:
0x1040, Gr8InitReg
Width: 32 bit
The Gr8TrmMem cells are written with 0x0000 from TsiInitValReg during the first 27ms after
power-on reset, thus disabling all output channels. A re-initialization in the same manner can
be started later again by Gr8InitReg. The initialization process can be monitored with
Gr8InitMonReg.
9.5.2.5.2 Gr8 Initialization Monitor Register
Address:
0x1044, Gr8InitMonReg
Width: 32 bit
The Gr8TrmMem initialization and can be monitored (takes 18-27ms).
Bit
Acronym
Type
Description
Default
Pwr
Soft
31..
.16
-
-
reserved
undef
-
-
15..
.0
Gr8InitStart
W
0xCEEC: Gr8InitStart, Write 0xCEEC to
start Tsi initialization
0b0
F
F
Bit
Acronym
Type
Description
Default
Pwr
Soft
31..
.1
-
-
reserved
undef
-
-
0
Gr8InitDone
R
0b1: Gr8InitDone, Tsi initialization
done after power-on reset or
initialization restart by TsiInitReg, reset
by power on or when initialization is
started by TsiInitReg
0b0
F