4-17

Symptoms / Indications

Corrective Action

Output failure, continued

for Picopath interfaces with the test kit (228833):
See the Diagnostics tests section, earlier in this manual.
for Picopath interfaces without the test kit:
1. Go to the Setups > Diagnostics > I/O > Enter Machine password.
2. Exercise the output through the CNC to see if the output reacts as expected. If

an output point fails, replace and retest in this order:
• Picopath interface board
• Picopath MCC board
• Picopath I/O ribbon cable (223232)

3. If the output point still fails, a table component has failed and should be repaired

or replaced.

Hypernet
Communications with

components connected to

the HyperNet are not working

properly.

See the Diagnostics tests section, earlier in this manual.

LAN connection
•  Downloading part programs

over the LAN are not working

properly

•  Previously mapped network

drives are not shown when

trying to load a part program

See the Diagnostics tests section, earlier in this manual.