English

PRoDUCt StEWARDSHIP

Residual current devices (RCDs)
In Australia and some other countries, local codes may

require the use of a Residual Current Devices (RCD)

when portable electrical equipment is used in the

workplace or at construction sites to protect operators

from electrical faults in the equipment. RCDs are designed

to safely disconnect the mains electrical supply when

an imbalance is detected between the supply and return

current (there is a leakage current to earth). RCDs are

available with both fixed and adjustable trip currents

between 6 to 40 milliamperes and a range of trip times

up to 300 milliseconds selected for the equipment

installation, application and intended use. Where RCDs

are used, the trip current and trip time on RCDs should

be selected or adjusted high enough to avoid nuisance

tripping during normal operation of the plasma cutting

equipment and low enough in the extremely unlikely event

of an electrical fault in the equipment to disconnect the

supply before the leakage current under a fault condition

can pose a life threatening electrical hazard to operators.
To verify that the RCDs continue to function properly

over time, both the trip current and the trip time should

be tested periodically. Portable electrical equipment

and RCDs used in commercial and industrial areas in

Australia and New Zealand are tested to the Australian

standard AS/NZS 3760. When you test the insulation

of plasma cutting equipment to AS/NZS 3760, measure

the insulation resistance according to Appendix B of

the standard, at 250 VDC with the power switch in the

ON position to verify proper testing and to avoid the

false failure of the leakage current test. False failures

are possible because the metal oxide varistors (MOVs)

and electromagnetic compatibility (EMC) filters, used to

reduce emissions and protect the equipment from power

surges, may conduct up to 10 milliamperes leakage

current to earth under normal conditions.
If you have any questions regarding the application or

interpretation of any IEC standards described here, you

are required to consult with an appropriate legal or other

advisor familiar with the International Electrotechnical

standards, and shall not rely on Hypertherm in any

respect regarding the interpretation or application of such

standards.

Safe installation and use of shape cutting

equipment

IEC 60974-9, titled Arc Welding Equipment – Installation 

and use, provides guidance in the safe installation and

use of shape cutting equipment and the safe performance

of cutting operations. The requirements of national and

local regulations shall be taken into consideration during

installation, including, but not limited to, grounding or

protective earth connections, fuses, supply disconnecting

device, and type of supply circuit. Read these instructions

before installing the equipment. The first and most

important step is the safety assessment of the installation.
The safety assessment must be performed by an expert,

and determines what steps are necessary to create a safe

environment, and what precautions should be adopted

during the actual installation and operation.

Procedures for periodic inspection and

testing

Where required by local national regulations, IEC 60974-4

specifies test procedures for periodic inspection and

after repair or maintenance, to ensure electrical safety

for plasma cutting power sources built in conformity with

IEC 60974-1. Hypertherm performs the continuity of the

protective circuit and insulation resistance tests in the

factory as non-operating tests. The tests are performed

with the power and ground connections removed.
Hypertherm also removes some protective devices

that would cause false test results. Where required by

local national regulations, a label shall be attached to

the equipment to indicate that it has passed the tests

prescribed by IEC60974-4. The repair report shall indicate

the results of all tests unless an indication is made that a

particular test has not been performed.

qualification of test personnel

Electrical safety tests for shape cutting equipment can be

hazardous and shall be carried out by an expert in the field

of electrical repair, preferably someone also familiar with

welding, cutting, and allied processes. The safety risks

to personnel and equipment, when unqualified personnel

are performing these tests, may be much greater than the

benefit of periodic inspection and testing.
Hypertherm recommends that only visual inspection be

performed unless the electrical safety tests are specifically

required by local national regulations in the country where

the equipment is installed.