HyPath inputs

•  Use positive logic that requires a positive voltage to activate the input.
•  Are opto-coupled and have a range of +4.7 V minimum to +32 V maximum. Internal series resistor = 4.7 K Ohm.
•  +24 VDC field power supply on the HyPath and 4-axis servo PCB with a total external usage of 1.5 A.

•  Connection to a opto-isolator, typically found in a THC and a plasma supply.

HyPath input circuit examples
•  Connection to a limit switch, a push-button switch, a home switch, a station select switch (toggle switch), a relay

contact, or an emergency-stop button

+5 VDC

+24 VDC

4.7 k

Input

Common

Shield

37

Customer supplied cable

Customer-supplied, normally open switch

Customer circuit

MicroEDGE Pro

+5 VDC

+24 VDC

4.7 k

Shield

37

Customer supplied cable

Customer-supplied opto-isolator switch

Customer circuit

MicroEDGE Pro

VDC

Input

Common