Serial port configuration, Serial ports 1 and 2, Serial ports 3 and 4 – Hypertherm MicroEDGE Pro Shape Cutting Control Rev.2 User Manual
Page 81: Serial port configuration -33, Serial ports 1 and 2 -33 serial ports 3 and 4 -33

InstallatIon
MicroEDGE Pro
Instruction Manual 807290
2-33
Serial port configuration
The serial ports in the MicroEDGE Pro are designed to operate with a standard 9-pin serial port connector. The
following list provides specifications for these ports. For more information, see the Phoenix Software Installation and
Setup manual.
Serial isolation specifications (see Machine Setups > Ports In Phoenix software)
Channel Type
Optically isolated RS-422 or RS-232
Information Code
ASCII
Baud Rate
User-selectable up to 115.2K baud
Number of Start Bits
1
Number or Stop Bits
1
Word Length
User-selectable 7 or 8 bits
Parity
User-selectable none, even or odd
Data Synchronization
XON (Control-Q) / XOFF (Ctrl/S)
Time Out
User-selectable in one-second increments
Transmit Delay
User-selectable in 0.01-second increments
Rear Panel Connector
IBM-PC/AT compatible 9-pin D-type female
Serial ports 1 and 2
The default configuration for serial ports 1 and 2 on the motherboard is RS-232. These ports cannot be reconfigured.
Serial ports 3 and 4
Both serial ports on the following boards are shipped in the RS-422 wiring configuration:
• HyPath and Picopath 4-axis MCC, utility, and serial isolation board (141222)
• Picopath 2-axis MCC, utility, and serial isolation board (141256)
• SERCOS II and SERCOS III utility and serial isolation board
(141194/141307)
To change either port to an RS-232 configuration, you must find the jumper
for the appropriate port and move the jumper from the RS-422 position to the
RS-232 position. These positions are clearly marked on the board.
Configure the port for RS-232 operation before connecting RS-232 compatible
devices.
Serial port
3
Serial port
4
RS-232
RS-422
RS-232
RS-232
RS-422
Jumpers in
RS-422 position