SERCoS III I/o configuration

The MicroEDGE Pro SERCOS III I/O configuration conforms to the SERCOS III standard. The full details of this

specification cannot be addressed in this manual. Refer to the Phoenix Software V9 Series Installation and Setup

Guide (806410) for instructions about how to set up your EDGE Pro SERCOS III CNC. For complete information about

SERCOS technology and specifications, refer to: http://www.sercos.com.

Rear view of the SERCoS III MicroEDgE Pro CNC

SERCoS III Cable

A shielded Cat-5e Ethernet cable connects the SERCOS III I/O interface on the rear of the CNC enclosure to the

drive amplifier cabinet. A minimum of one cable is required for this connection to create a single SERCOS III line that

connects Port 1 (P1) on the CNC and all the SERCOS III drives in the drive amplifier cabinet.

To create a SERCOS III ring that will provide communication redundancy and security, connect a second cable

between Port 2 (P2) on the CNC and the drive amplifier cabinet.

Part number

Length

Part number

Length

223212

3.0 m (10 ft)

223099

23.0 m (75 ft)

223222

6.0 m (20 ft)

223100

30.5 m (100 ft)

223119

7.5 m (25 ft)

223101

45.5 m (150 ft)

223223

10.5 m (35 ft)

223102

61.0 m (200 ft)

223008

15.0 m (50 ft)