Picopath connections

Picopath I/o connections

I/O assignments are made in the Phoenix software on the Machine Setups > I/O screen. For more information, see the

Phoenix Software Installation and Setup Manual.

Rear view of the MicroEDgE Pro CNC with Picopath I/o configuration

Picopath I/O offers:
•  12 negative logic inputs rated at 24 VDC
•  12 negative logic outputs, rated at 24 VDC for up to 1 A loads
•  24 VDC field power supply on the Picopath PCB with a total usage of 1.5 A