InstallatIon
MicroEDGE Pro
Instruction Manual 807290
2-21
Connection to a relay coil (2a and 2b). The field voltage is supplied by the customer.
2a.
+24 VDC
Output A
Common
Shield
37
Customer supplied cable
24 VDC coil – CNC sourced
Customer circuit
MicroEDGE Pro
Output B
Relay
003179
24 VDC coil,
with diode
+24 VDC
Output A
Common
Shield
37
Customer supplied cable
AC relay – supplied by customer
Customer circuit
MicroEDGE Pro
Output B
Relay
003179
AC relay
VAC
1c.