Hypath outputs, Hypath output circuit examples, Hypath outputs -20 – Hypertherm MicroEDGE Pro Shape Cutting Control Rev.2 User Manual

Page 68: Hypath output circuit examples -20, Installation 2-20

Advertising
background image

InstallatIon

2-20

MicroEDGE Pro

Instruction Manual 807290

HyPath output circuit examples
Connection to a relay coil (1a, 1b, and 1c). Notice that the commons are connected together and a diode (supplied by

the customer) is used between DC coil connections.

1a.

HyPath outputs

•  Use relay contact closure (003179). The relay outputs are normally open contacts. Outputs can be set to normally

closed by setting the output logic in the I/O screen in the Phoenix software.

•  5 V to 32 V switching voltage; 5 A continuous-resistive load; 2 A continuous-inductive load.

+24 VDC

Output A

Common

Shield

37

Customer supplied cable

AC coil – supplied by customer

Customer circuit

MicroEDGE Pro

Output B

Relay

003179

AC coil

VAC

+24 VDC

Output A

Common

Shield

37

Customer supplied cable

24 VDC coil – CNC sourced

Customer circuit

MicroEDGE Pro

Output B

Relay

003179

24 VDC coil, with

diode

1b.

Advertising