Hypath outputs, Hypath output circuit examples, Hypath outputs -20 – Hypertherm MicroEDGE Pro Shape Cutting Control Rev.2 User Manual
Page 68: Hypath output circuit examples -20, Installation 2-20

InstallatIon
2-20
MicroEDGE Pro
Instruction Manual 807290
HyPath output circuit examples
Connection to a relay coil (1a, 1b, and 1c). Notice that the commons are connected together and a diode (supplied by
the customer) is used between DC coil connections.
1a.
HyPath outputs
• Use relay contact closure (003179). The relay outputs are normally open contacts. Outputs can be set to normally
closed by setting the output logic in the I/O screen in the Phoenix software.
• 5 V to 32 V switching voltage; 5 A continuous-resistive load; 2 A continuous-inductive load.
+24 VDC
Output A
Common
Shield
37
Customer supplied cable
AC coil – supplied by customer
Customer circuit
MicroEDGE Pro
Output B
Relay
003179
AC coil
VAC
+24 VDC
Output A
Common
Shield
37
Customer supplied cable
24 VDC coil – CNC sourced
Customer circuit
MicroEDGE Pro
Output B
Relay
003179
24 VDC coil, with
diode
1b.