One output head cannot be assigned to more than one display at a time. When
different displays are assigned the same output head, if the displays are part of the
same room, then XEdit will issue an error message and prevent you from saving the
room until the head assignment is corrected.

However, to facilitate room management — for example, in a cluster system where
rooms and layouts have been created based on configurations from earlier standalone
systems — XEdit will let you assign the same head to displays that are located in
different rooms,
but such conflicting assignments will be marked in red in the filtered
System list displayed in the Tools pane, and should be resolved by removing a
conflicting display (see

Removing Displays

on page 214), or by deleting the conflicting

room (see

Deleting Rooms

on page 211).

Card slot letter (A, B, etc.)

Output head (1, or 2)

System name (cluster systems only)

Conflicts