5 connect the encoders, 6 secure the cables, 7 configure the dhcp router – HEIDENHAIN MSE 1000 User Manual
Page 113: 8 install the software, 9 open the software

Installation and commissioning examples
Example using DHCP IP address assignment
Operating Instructions
113
10.1.5
Connect the encoders
Connect the 1 V
PP
encoder
Connect the 1 V
PP
encoder to the MSE 1184 (ID 747500-01) X1 connector
17
. Refer
to "Connecting a 1 VPP encoder", page 29.
Connect the EnDat
encoder
Connect the EnDat encoder to the MSE 1314 (ID 747503-01) X11 connector
16
.
Refer to "Connecting an EnDat encoder", page 28.
10.1.6
Secure the cables
Install cable mounting
hardware
Install the cable mounting hardware provided with each module. Refer to "Installing
cable mounting hardware", page 21.
Secure cables
Secure all cables to the cable mounting hardware using the supplied cable tie's.
10.1.7
Configure the DHCP router
Configure the DHCP
router
Connect to the router through the router utility. This is usually a web browser. Refer
to the documentation provided with the router for instructions.
Set the IP address of the router to 172.31.46.3.
Set the netmask to 255.255.255.0.
Set the address range for 172.31.46.4 to 172.31.46.255.
Set the lease time to Forever.
Disable SNTP.
10.1.8
Install the software
Install MSEsetup
Download and install the MSEsetup application software. Refer to "Installing
MSEsetup", page 34.
10.1.9
Open the software
Open MSEsetup
Double-click the MSEsetup desktop icon to open MSEsetup. Refer to Opening
MSEsetup"", page 48.