8.1.4

Individual Module IP

Individual Module IP options are used for querying or setting a static IP address for a
specific module in the module chain. The Query option is available even when there is
not an active connection between the workstation and the MSE 1000 modules.

The workstation NIC and MSE 1000 base module must be connected with
an ethernet cable for Individual Module IP options to function.

Select a module with
an active connection

The Individual Module IP drop-down list is available when there is an active
communication connection between the workstation and the MSE 1000 modules.

To select a module from the drop-down list:

Click the Individual Module IP drop-down arrow and select a module from the list.

Select a module
without an active
connection

Individual Module IP text fields are enabled when there is not an active connection
between the workstation and the MSE 1000 modules. Which text fields are enabled
is determined by the Workstation IP netmask setting. Values automatically entered in
disabled text fields are determined by the IP address and the netmask specified in the
Workstation IP option.

To select a module by IP address:

Click inside an enabled text field and enter the required value to communicate
with a specific module. Repeat this step until all text fields have the required value
entered.

Query a module

The Query option sends a request to the selected module to determine the module
type. This is useful for testing if MSEsetup can communicate with a specific module.

To query a module:

Select a module using one of the methods described above.

Click the «Query» button.

Query results will be displayed in the Connect screen message area.

Set static IP address

The Set Static option sends a request to the selected module to change the static IP
address to the value specified in the Set Static text fields. Which text fields are enabled
is determined by the Workstation IP netmask setting. An active connection is required
when setting a static IP address.

To set a static IP address:

Click the Individual Module IP drop-down arrow and select a module from the list.

Click inside an enabled Set Static text field and enter the desired value. Repeat this
step until all Set Static text fields have the desired value entered.

Click the «Set Static» button.

MSEsetup sets the static IP address and performs a reconnect to the modules.