1 module specifications, Er to "module specifications – HEIDENHAIN MSE 1000 User Manual
Page 158

Technical specifications
Module specifications
158
Operating Instructions
14.1
Module specifications
Refer to "Power consumption calculation example", page 18.
MSE 1201, MSE 1202: Power supply modules
MSE 1201
(ID 747501-01)
MSE 1201
(ID 747501-02)
MSE 1202
(ID 747502-01)
Power
input
AC 100 V ... 240 V (±10 %)
50 Hz ... 60 Hz (±2 %)
(max. 108 W)
DC 24 V (±10 %)
(max. 72 W)
Rated power
output
50.4 W
72 W
Replaceable
fuse
T 1 A / 250 V,
5 mm x 20 mm Qty. 2
T 3.15 A / 250 V,
5 mm x 20 mm
Data
transfer
Standard Ethernet, IEEE 802.3
Addressing
Fixed IP address or DHCP
Operating
temperature
0 °C ... 45 °C
Storage
temperature
-20 °C ... 70 °C
Relative
humidity
≤ 80 %
Altitude
≤ 2000 m
Degree of
protection
IP40
IP65
IP65
Overvoltage
category
II, intended to be supplied from the building wiring
Pollution
degree
2
Mass
720 g
960 g
560 g