Function reserves
The Function Reserves screen is used to display absolute track, incremental track and
position value formation bar diagrams. The result is displayed in %. A drag indicator
(square above the bar display) marks the minimum.
Function reserves ranges:
Green range: The output signal is within the specifications.
Yellow range: The output signal is outside the specifications, but no counting or
calculation errors are to be expected. No alarms are generated, warnings may occur.
NOTICE
The yellow range indicates service or maintenance recommended.
Refer to the documentation provided with the encoder for additional information on
EnDat function reserves.
Function reserves:
Absolute track
Incremental track
Positions value
Function reserves
screen