Advanced Programming

3.1.4 USER FUNCTION CALL (UFC)

3 -12

An example of the transfer of I/O registers is shown in the following illustration.

UFC TESTFUNC DB00000 DB000001 MW00030 MW00032 MA00100,DB000002 MW00040

Motion program code

DB000000

DB000001

MW00030

MW00032

DB000002

MW00040

YW00000
YW00001
YW00002

YW00015

S
S
S
S
S
S
S
S
S
S
S
S

MW00100
MW00101
MW00102

S
S
S
S
S
S
S
S
S
S
S
S

AW00000
AW00001
AW00002

MA00100

XW00000
XW00001
XW00002

XW00016

X registers

Y registers

Figure 3.6

Motion Program Coding

J

Creating User Functions

This section describes the procedure for creasing user functions with an example using the fol-
lowing specifications for an MP930 Machine Controller. For MP2000-series Machine Control-
lers, the parameter addresses are different from the address shown in the following table.

Specifications

Designate the servo axis No. and speed data, and set this in the Rapid Tra-
verse Speed setting parameter (OLxx22).

Motion Program

MW00030 = Servo axis No. (1 or 2)
ML00032 = Rapid traverse speed
UFC FUNC-T1 MW00030 ML00032, DB000001;