Jprogramming examples – Yaskawa MP900 Series Motion Programming Manual User Manual

Page 181

Advertising
background image

5.2 Using Variables

5 -11

Table 5.5 MP2000-series Machine Controller Motion Parameter Register Numbers

Axis No.

Line No.

No.1 axis

No.2 axis

No.3 axis

No.4 axis

No.5 axis

¡ ¡

No.14 axis

1

8000 to 807F

8080 to 80FF

8100 to 817F

8180

to

81FF

8200 to 827F

¡ ¡

8780 to 87FF

2

8800 to 887F

8880 to 88FF

8900 to 897F

8980

to

89FF

8A00

to

8A7F

¡ ¡

8F80

to

8FFF

3

9000 to 907F

9080 to 90FF

9100 to 917F

9180

to

91FF

9200

to

9A7F

¡ ¡

9780

to

97FF

4

9800

to

987F

9880 to 98FF

9900 to 997F

9980

to

99FF

9A00

to

997F

¡ ¡

9F80

to

9FFF

5

A000 to A07F

A080 to A0FF

A100 to A17F

A180

to

A1FF

A200

to

A27F

¡ ¡

A780

to

A7FF

6

A800 to A87F

A880 to A8FF

A800 to A87F

A980

to

A9FF

AA00

to

AA7F

¡ ¡

AF80

to

AFFF

7

B000 to B07F

B080 to B0FF

B100 to B17F

B180

to

B1FF

B200

to

B27F

¡ ¡

B780

to

B7FF

8

B800 to B87F

B880 to B8FF

B900 to B97F

B980 to B9FF

BA00

to

BA7F

¡ ¡

BF80

to

BFFF

9

C000 to C07F

C080 to C0FF

C100

to

C17F

C180 to C1FF

C200

to

C27F

¡ ¡

C780

to

C7FF

10

C800 to C87F

C880 to C8FF

C900

to

C97F

C980 to C9FF

CA00

to

CA7F

¡ ¡

CF80

to

CFFF

11

D000 to D07F

D080 to D0FF

D100

to

D17F

D180

to

D1FF

D200

to

D27F

¡ ¡

D780

to

D7FF

12

D800 to D87F

D880 to D8FF

D900

to

D97F

D980 to D9FF

DA00

to

DA7F

¡ ¡

DF80 to DFFF

13

E000 to E07F

E080 to E0FF

E100

to

E17F

E180

to

E1FF

E200

to

E27F

¡ ¡

E780

to

E7FF

14

E800 to E87F

E880 to E8FF

E900

to

E97F

E980 to E9FF

EA00

to

A97F

¡ ¡

EF80

to

EFFF

15

F000 to F07F

F080 to F0FF

F100

to

F17F

F180 to F1FF

F200

to

F27F

¡ ¡

F780 to EFFF

16

F800 to F87F

F880 to F8FF

F900

to

F97F

F980 to F9FF

F900

to

F97F

¡ ¡

FF80

to

FFFF

Module No. Offset

The resister number for each axis in the servo monitor parameter is obtained using the following formula:

MP900-series Machine Controllers

S

Axis monitor parameter resister address = IW0000 + module number offset + (axis No.1)× 40 (HEX)

MP2000-series Machine Controllers

S

Axis monitor parameter resister address = IW0000 + module number offset + (axis No.1)× 80 (HEX)

J

Programming Examples

External output signals and servo monitor parameters are read out and referenced.

D

Bit Designation

MB01000 = IB0010 & IB00105;

D

Integer Designation

MW0100 = IWC016;

D

Double Integer Designation

ML0100 = ILC022;

5

INFO

Advertising
This manual is related to the following products: