3 input variables (i registers) – Yaskawa MP900 Series Motion Programming Manual User Manual

Page 179

Advertising
background image

5.2 Using Variables

5 -9

When the travel d istance coordinate values or sp eed is designated as a variab le in the following mo tion com-
mands, double integer data must be used.
MOV, MVS, MCW/MCC, ZRN, SKP, MVT, EXM, POS, ACC, SCC, IAC, IDC, IFP, FMX, INP

5.2.3 Input Variables (I Registers)

J

Overview

These variables are used by external input signals and the servo monitor parameters. Although
servo parameters can also be used for writing data, the values cannot be guaranteed.

J

Description

I registers are designated as follows:

D

MP910

IW0000 to IW13FF

: External input signals

IWC000 to IWC77F

: Servo monitor parameters

D

MP920

IW0000 to IW13FF

: External input signals

IWC000 to IWFF7F

: Servo monitor parameters

D

MP930

IW0000 to IW07FF

: External input signals

IWC000 to IWC37F

: Servo monitor parameters

D

MP940

IW0000 to IW07FF

: External input signals

IWC000 to IWF03F

: Servo monitor parameters

D

MP2000 Series Machine Controller

IW0000 to IW7FFF

: External input signals

IW8000 to IWFFFF

: Servo monitor parameters

External Input Signal Register Numbers

D

Depends on the address specified in the Module configuration definition.
Local inputs in the MP930 MC350 module are fixed to IW0000 (IB00000 to IB0000F, 16
points).

Servo Monitor Parameter Register Numbers

The number of controlled axes depends on the module type. The following indicates the num-
ber of controlled axes for each module and the maximum number of modules.

5

IMPORTANT