3.2 Speed and Acceleration/Deceleration Commands

3 -39

J

Programming Examples

INC;

FMX T1000000;

IAC T1000;

IDC T1500;

MVS [axis1] 100000 F700000;

v

1,500 ms

1,000 ms

t

FMX setting

speed

F designation

speed

Figure 3.22 Programming Example for MAXIMUM INTERPOLATION FEED SPEED

SETTING (FMX)

1. When FMX is not designated in a motion program that uses interpolation commands, an alarm will be

generated. Program carefully.

2. A decimal point cannot be used directly in the FMX designation. The setting is made by adding the re-

quired number of zeroes after the decimal point.

Example: Number of digits after the decimal point = 3

Reference unit = mm
Maximum interpolation speed is 50000.000 mm ⋅⋅⋅
To set the above, input as follows:

FMX T50000000;