3.2 Speed and Acceleration/Deceleration Commands

3 -41

J

Programming Examples

FMX T10000;

INC;

IAC T1000;

MVS [axis1] 100000 F70000;

IAC T500;

MVS [axis1] 100000;

1,000 ms

v

t

FMX setting speed

F designation speed

500 ms

Figure 3.24 Programming Example for INTERPOLATION ACCELERATION TIME

CHANGE (IAC)

Before designating the IAC command, set the maximum interpolation feed speed in the FMX command. If
the IAC command is designated without first designating the FMX command, an error will result.