5.2.1.B RS-485 Readers

For long-distance connection and non-Wiegand card readers, you can connect RS-485
connection with any GV-Readers and GV-GF Fingerprint

Readers. Using a single RS-485

cable, up to

8 readers

can be connected together with to the RS-485 A+ / A- interface. For

GV-AS810 / 8110, another 8 readers can be connected to the RS-485 B+ / B- interface, for a
total of

16 RS-485 readers

.


When multiple readers are connected together, an extra power supply to each unit is
required. Use

12V

power output

and

GND

on the power terminal or the Wiegand connectors

to power on each unit.

Connect each reader to the

power terminal or Wiegand

connectors for power supply

RS485

12

V

A+

A-

B+

B-

G

N

D

Up to 8 GV-Readers and

GV-GF Fingerprint Readers

12V OUTPUT

12

V

G

N

D

12

V

G

N

D

12

V

G

N

D

B+ B- Not functional

for GV-AS410 / 4110

RS

485

_A

RS

485

_B

Terminal

Resistor

J37

J35

Figure 5-3