GeoVision GV-AS2120 IP Control Panel User Manual

Page 157

Advertising
background image

The Web Interface

155

8
=
4
7

[Series Function (APB & Fire)]

This option lets you set the Anti-Passback function and fire sensor function across multiple
door controllers. The Anti-Passback means that a card used on an entry door cannot access
the same entry door again unless it has been used on a corresponding exit door. For details
on setup, see

Chapter 6 Anti-Passback

on

GV-

ASManager User’s Manual

.


For all zone fire sensor function, the fire sensors on all associated controllers will be
triggered when the fire sensor on one door is triggered. For this function to work, you must
set the Input Type to

All Zone

. For details, see the

Input Setting

section later in this chapter.

Enable/Disable:

Enables or disables the Anti-Passback function and fire sensor function.

Info IP:

Enter the IP address of the next corresponding controller.


Click

Submit

button to save the changes, or click

Cancel

button to return the changes to its

previous state.


Note:

The all zone fire sensor function is only supported by GV-AS210 / 2110 / 2120 / 410 /

4110 / 810 / 8110 firmware V1.23 or later.

Advertising