2 installation – GeoVision GV-AS2120 IP Control Panel User Manual

Page 56

Advertising
background image

54

2.2 Installation

The wire assignment of the GV-AS110 cable data are illustrated below.

Front View

Figure 2-4

Rear View

GV-AS110

Red

12VDC

LBlue

RS485-

Black

GND

Green

Wiegand

DATA0

Blue

RS485+

White

Wiegand

DATA1

Yellow

Input-Door

Purple

Alarm-COM

Orange

Input-

Button

Gray

Alarm-

NO

LRed

Input-

Fire

Brown/

White

Door-

COM

Brown

Input-

COM

Black/

White

Door-

NC

LGreen

Door-

NO

GV-AS110

Wire color

Definition

Red

12V DC

Black

GND

Green

Wiegand Data 0

White

Wiegand Date 1

Blue

RS485+

Light Blue

RS485-

Yellow

Door Sensor IN1

Orange

Button IN2

LRed

Fire Sensor IN3

Brown

IN COM (GND)

Purple

Alarm COM

Gray

Alarm NO

Brown White

Door COM

Black White

Door NC

Light Green

Door NO

Figure 2-5