GeoVision GV-AS2120 IP Control Panel User Manual

Page 214

Advertising
background image

212

Below is the explanation based on the numbers marked on the above figure.

1. ASBOX Input #:

Edit the name of the Input.

2. NO/NC:

Configure the input to

NC

(normally closed) or

NO

(normally open) mode.

3. Input Type:

Configure the input type to define the type of sensor that is connected to the

input of GV-ASBox. Options available for the input type change based on your settings of

Door/Gate A

and

Door/Gate B

in the

Function Setting

page (Figure 9-15).

4. Input Function:

Configure the input function. Options available for the input function

change based on the settings of

Input Type

above.

When

Door Entry/Exit Control

is selected in the

Function Setting

page (Figure 9-15),

these

Input Type

and

Input Function

become available:

Input Type

Input Function

Description

Normal Input

Enable Latch
Disable Latch

The Normal Input is used for a normal

detection mode in which the input is set to

trigger an output. Instead of constant output

alarm in N/O and N/C, the

Enable Latch

option provides a momentary alarm when

triggered.

Door A or B

Fire Zone
Tamper Zone
Exit Button
Door Contact

Depending on the type of sensor and the

location where it is installed, select the best

Input Function name to fit the sensor

description. When the sensor is activated, an

alarm event occurs and the alarm device can

be triggered. For alarm events, see [Alarm],

9.3.2.B Parameter Setting

.

For example, when the

Door Contact

sensor

detects unauthorized access, a “Force Open”

event occurs and it can trigger the “Force

Open” alarm.