2 programming the gv-as110 / 1110 – GeoVision GV-AS2120 IP Control Panel User Manual

Page 68

Advertising
background image

66

2.3.2 Programming the GV-AS110 / 1110

The command codes used to program various functions on GV-AS110 / 1110 are listed
below. All command codes will start with an asterisk

to clear all previous commands and

end with a number sign # to send the command. After typing the command code, present
the Enroll Card or the Delete Card.

IMPORTANT:

Once connecting to GV-AS110 / 1110, GV-ASManager will load its

parameters to GV-AS110 / 1110. That means some of settings you program here may be
overwritten by GV-ASManager later.

Function

Command Code

Description

Set Password

779_ _ _ _ _ _ _ _ #

4-8 digits

You can set a password to open the door using

this password. The Authentication Mode must

be set to

Fixed Card/Common

mode. Refer to

the

Set Authentication Mode

function below.

For example, to set the door’s password as

12345, press

77912345# on the keypad.

Lock Reset
Time

578_ _ _ #

1-255 seconds

Sets a time that the door/gate will remain open

after which the door will automatically be

locked.
For example, to set the lock reset time to be

120 seconds, press

578120#

Held Open
Time

468_ _ _ _ #

5-9999 seconds

Sets the time that a door/gate can be held open

before an alarm is generated. If the number of

seconds is less than 4 digits, add zeros in front

of them to make it 4 digits.
For example, to set the held open time to be

180 seconds, enter

4680180#

Set Fire Action

(GV-AS110
only)

732_#

Unchanged

0

Unlock Door

1

Lock Door

2

This function locks or unlocks the door/gate, or

maintains the current status when a fire

emergency occurs.
For example, to unlock door during a fire

emergency, press

7321#

Local Anti-
Passback

527_#

0

Disable

1

Enable

Local Anti-passback prevents card sharing by

not allowing a card to go through an entry twice

before first exiting.
For example, to enable Local Anti-passback,

press

5271#

Advertising