2 connecting input devices – GeoVision GV-AS2120 IP Control Panel User Manual

Page 30

Advertising
background image

28

1.2.2 Connecting Input Devices

GV-AS100 / 1010 supports 3 types of inputs:

1. Sensor inputs, e.g. door status sensor

2. Button inputs, e.g. door opener

3. Fire Sensor inputs, e.g. fire detector

All inputs are

dry contact

and can be configured as normally open (NO) or normally closed

(NC) through the GV-AS100 / 1010 keypad. The default value is

NO

. To change the input

status, see the

Set Contact Type

option in

1.3.5 Setting Parameters

.

The table below shows the pin assignments of input connectors on GV-AS100 and GV-
AS1010.

GV-AS100

Pin Function

11 Sensor IN1
12 Button IN2
13 Fire Sensor IN3
14 IN COM

GV-AS1010

Pin Function

7

IN COM

8

Input Fire

9

Input Button

10 Input Sensor