[Events]

Set the parameters for the events.

When

Door Control

is selected in

the

Function Configuration

page (Figure 8-8), these

options become available:

Option

Description

Anti-Passback

Enables or disables the Anti-Passback function.

Lock Reset Time

Sets the time (1 to 600 sec.) that a door remains open after which

the door will automatically be locked.

Held Open Time

Sets the time (5 to 9999 sec.) that a door can be held open before

an alarm is generated.

Fire Action

Locks or unlocks the door when a fire condition occurs. Otherwise,

remains the door’s current state by selecting

Unchanged

.

Alarm Continuous

Time

Sets the time (1 to 10 sec.) that the alarm will continuously go off

before it ends.

Note:

The Lock Reset Time of 1 to 600 seconds is only supported by GV-AS21 / 41 / 81

series Controller firmware V2.0 or later.

When

Parking Control

is selected in

the

Function Configuration

page (Figure 8-8),

these options become available:

Option

Description

Anti-Passback

See the same option above.

Relay On Time

Sets the time (1 to 255 sec.) that a gate remains open after which

the gate will automatically be closed.

Held Open Time

See the same option above.

Fire Action
Alarm Continuous

Time

When

Elevator Control

is selected in the

Function Configuration

page (Figure 8-8),

these options become available:

Option

Description

Relay on Time

See the same option above.

Fire Action
Alarm Continuous

Time

See the same option above.