In the Output Condition settings, these

Output Type

and

Output Condition

become

available:

Output Type Output Condition

Door #

Gate #

Relay #

Input/Reader

Normal
Toggle
Pulse

Access Granted Access Granted Access Granted Select

None

to

disable the

condition, or select

an Input, Wiegand,

or Reader to

trigger the output.

Access Denied

Access Denied

Access Denied

Fire Alarm

Fire Alarm

Fire Alarm

Tamper

Tamper

Tamper

Duress Event

Duress Event

Duress Event

Held Open

Held Open

Forced Open

Forced Open

Exit Button

Exit Button

Door Contact

Car Detection

Click

Reset

button to return the

Normal

,

Toggle

or

Pulse

triggered state to be normal.

Click

Submit

button to save the changes, or click

Cancel

button to return the changes to its

previous state.

Note:

The

Reset

button is more commonly used for the

Toggle

output because once

triggered, the output will go on forever. A

Reset

button is needed to turn it off.