Q6: The GV-ASManager cannot receive card messages from the GV-Reader

connected to the GV-AS / GV-EV Controller through RS-485 interface.

1. Make sure the GV-Reader is correctly wiring to the controller and Switch 4 on the GV-

Reader is set to OFF.

2. Make sure the correct GV-Reader ID is set on the controller.

Q7: The GV-AS Controller does not respond to reader(s) connected through its

Wiegand interface.

If the Wiegand reader is correctly wired but the information received isn’t transmitted to the
GV-AS Controller, this may be due to insufficient voltage on the controller’s Wiegand port.
Click

here

to troubleshoot for this issue.

Q8

: I can’t change the Advanced Settings on the Web interface of the GV-AS /

GV-EV Controller. The

“Submit” button is missing.

To modify the Advanced Settings, make sure the

Web Setting Switch

on the controllers is

set to ON. For the location of the Web Setting Switch, refer to the

Web Setting Switch

section of each GV-AS / GV-EV Controller or GV-ASNet / GV-ASBox.