7. The connection between the GV-ASManager and controller should be established, and

the connection icon should appear. If disconnection happens after you connect the
hub or switch to the network, then it should be other network problems. Please contact
your network administrator.

Q2: The connection established between the GV-ASManager and GV-AS / GV-

EV Controller is interrupted.

This may be due to IP address conflict. Follow these steps to troubleshoot the problem:

1. Disconnect the hub or switch, which connects to the GV-ASManager and the controller,

from the network.

2. Run Windows

Command Prompt

. Take Classic Windows Start Menu for example, click

Start

, select

Accessories

and click

Command Prompt

.

3. Type

arp

–d

and press

Enter

.

Figure 10-4

4. Give the GV-ASManager a fixed IP address that is NOT used by another device. See

Figure 10-1.

5. Open the browser and enter the assigned IP address of the controller. The Network

Configuration page appears. See Figure 10-2.

6. In the IP address field, give the GV-AS / GV-EV Controller an IP address that is NOT

used by another device, e.g. 192.168.0.XXX.

7. On the GV-ASManager, enter the following settings. See Figure 10-3.

Controller ID:

1

Network:

TCP/IP

IP:

192.168.0.XXX

Port:

4000

Advertising