Optional Devices

215

9

Output Function Settings:

When

Output Type

(No. 1, Figure 9-25)

is set to be

Door #

,

Gate #

or

Relay #

, the options

similar to the figure below become available.

Figure 9-26

Below is the explanation based on the numbers marked on the above figure.

1. ASBOX Output #:

Edit the name of the Output.

2. Output Type:

Configure the output type. Options available for the output type change

based on your settings of

Door/Gate A

and

Door/Gate B

in the

Function Setting

page

(Figure 9-15).

3. Output Function:

Configure the output function. Options available for the output

function change based on your setting of

Output Type

above.

When

Door Entry/Exit Control

is selected in the

Function Setting

page (Figure 9-15),

these

Output Type

and

Output Function

become available:

Output Type

Output Function

Description

Door #

Electric Lock

Output is triggered when the card is

presented to open the locking device.

Alarm Event

Output is triggered when the defined alarm

events occur.

Entry Card

Output is triggered when the card is

presented to enter the door.

Exit Card

Output is triggered when the card is

presented to exit the door.

1

2

3