4 installation, A connecting gv-as100 / 110 / 120 – GeoVision GV-AS2120 IP Control Panel User Manual

Page 187

Advertising
background image

Optional Devices

185

9

9.1.4 Installation

This section describes how to connect other devices to GV-ASBox.

9.1.4.A Connecting GV-AS100 / 110 / 120

The table and figure below show the pin assignments of related connectors on GV-ASBox
for connection to GV-AS100, GV-AS110 and GV-AS120

.

1 2

ON

GND

12V

A+

A-

B+

B-

GV-AS100

/110/12

0

GV-Read

ers

RS-485_

A T
ERM

RS-485_

B T
ERM

Figure 9-2

Pin

Function

Pin

Function

Pin

Function

12V 12V Power Supply to

GV-AS100/110/120

A+

GV-AS100/110/120

Connection

B+

GV-Readers

Connection

GND GND for Power Supply to

GV-AS100/110/120

A-

GV-AS100/110/120

Connection

B-

GV-Readers

Connection

Note:

1. By default,

RS-485_A Term

and

RS-485_B Term

are set to OFF.

2. When the distance between the GV-ASBox and the GV-AS100 / 110 / 120 is over a long

distance,

RS-485_A Term

must be switched to ON. When the distance between the

GV-ASBox and the GV-Readers is over a long distance,

RS-485_B Term

must be

switched to ON.