GeoVision GV-AS2120 IP Control Panel User Manual

Page 219

Advertising
background image

Optional Devices

217

9

Output Condition Settings:

When

Output Type

(No. 1, Figure 9-25) is set to be

Normal

,

Toggle

,

Pulse

,

Normal

Lighting

,

Toggle Lighting

or

Pulse Lighting

, the options similar to the figure below

become available.

Figure 9-27

There can be a maximum of 4 conditions that can be set up to trigger an output. 2 conditions
are Door/Gate/Relay conditions and 2 conditions are Input conditions. Each condition is
related to each other through

AND/OR

.

AND

means that all conditions with

AND

must be

triggered before the output is triggered.

OR

means that only 1 of the condition with

OR

is

needed to be triggered before the output is triggered. It is also valid to have certain
conditions as

AND

and certain conditions as

OR

.

Only

Output 5 ~ 8

can be connected to Lights. So

Normal Lightning

,

Toggle Lighting

and

Pulse Lighting

can only be selected from

Output 5 ~ 8

. For

Pulse

and

Pulse Lighting

, the

output is triggered for the amount of time set in the

Sec

field (seconds).

2 x Door/Gate/Relay Conditions

2 x Input Conditions

Available in

Pulse/Lighting