3 connecting output devices – GeoVision GV-AS2120 IP Control Panel User Manual

Page 80

Advertising
background image

78

3.2.3 Connecting Output Devices

GV-AS120 supports 1 type of output: Door outputs, e.g. electronic lock

The table below shows the wire assignments of output connectors on GV-AS120.

Wire color

Definition

Purple

Door COM

Orange

Door NC

Gray

Door NO

Check if your output device meets the following absolute maximum ratings before
connecting it to the Door outputs.

Breakdown Voltage

250V AC, 220V DC

Continuous Load Current

1A (30V DC), 0.3A (125V AC)

Note:

Absolute Maximum Ratings are those values beyond which damage to GV-

AS120 circuit board may occur. Continuous operation of GV-AS120 at the absolute
rating level may affect GV-AS120’s reliability.

To connect an output device:

The example below illustrates the connection of a locking device to GV-AS120. Connect the
(+) point on the locking device to the Door COM wire on GV-AS120, connect the two (-)
points of the locking device and the external power supply together, and connect the (+)
point on the external power supply to the Door NO or Door NC wire on GV-AS120 based on
the state of the locking device.

Locking Device

Purple, Door COM

Gray, Door NO

Orange, Door NC

External

Power

Supply

-

+

+

-

Figure 3-5

Advertising