B rs-485 readers – GeoVision GV-AS2120 IP Control Panel User Manual

Page 95

Advertising
background image

GV-AS210 / 2110 / 2120 Controller

93

4

4.2.1.B RS-485 Readers

For long-distance connection and non-Wiegand card readers, you can establish RS-485
connection with any GV-Readers and GV-GF Fingerprint Readers. Up to

8 readers

can be

connected together with a single RS-485 cable to the RS-485 interface on GV-AS210 / 2110
/ 2120.

When multiple readers are connected together, an extra power supply to each unit is
required. Use

12V

power output

and

GND

on the power terminal or the Wiegand connectors

to power on each unit.

GND

12V
D0
D1
GND

RS485 A+
RS485 A-

Wiegand

12V

RS485+

RS485-

12V

GND

Up to 8 GV-Readers and

GV-GF Fingerprint Readers

Connect each reader to the power terminal or

Wiegand connectors for power supply

Not

Functional

12V

GND

RS-485_A TERM

RS-485_B TERM (Not Functional)

GND

12V

Figure 4-4

Note:

1. Each set of 12V power output and GND can provide power for up to 2 readers. The 2

sets on the power terminal can support up to 4 readers. If you wish to connect more
readers and the Wiegand interfaces are already occupied, you can connect the
readers to an external power source.

2. When the RS-485 connection between GV-AS210 / 2110 / 2120 and the reader is over

a long distance, you can turn ON the RS485 A Terminal switch if the signal is
unstable.