Software Lock Mode

The software lock function keeps personnel from accidentally changing parameters in
the inverter memory. Use B_31 to select from various protection levels.

The table below lists all combinations of B_31 option codes and
the ON/OFF state of the [SFT] input. Each Check

✔ or Ex ✘

indicates whether the corresponding parameter(s) can be edited.
The Standard Parameters column below shows access is permit-
ted for some lock modes. These refer to the parameter tables
throughout this chapter, each of which includes a column titled
Run Mode Edit as shown to the right. The marks (Check

✔ or

Ex

✘) under the “Run Mode Edit” column title indicate whether access applies to each

parameter as defined in the table below. In some lock modes, you can edit only F_01 and
the Multi-speed parameter group that includes A_20, A220, A_21–A_35, and A_38
(Jog). However, it does not include A_19, Multi-speed operation selection. The editing
access to B_31 itself is unique, and is specified in the right-most two columns below.

NOTE: Since the software lock function B_31 is always accessible, this feature is not
the same as password protection used in other industrial control devices.

B_31
Lock

Mode

[SFT]

Intelligent

Input

Standard Parameters

F_01 and

Multi-Speed

B_31

Stop

Run

Stop & Run

Stop

Run

00

OFF

Run mode

edit access

ON

01

OFF

Run mode

edit access

ON

02

(ignored)

03

(ignored)

Run

Mode

Edit