Motor control acce ssor ie s – Hitachi SJ100 User Manual

Page 167

Advertising
background image

SJ100 Inverter

Motor Control

Acce

ssor

ie

s

5–9

The table below lists 400V-class inverter models
with built-in braking units. Depending on the
desired braking torque or on the inverter model,
the resistor selection specifies multiple resistors
in a parallel or series combination. The example
diagram shows a parallel configuration. Please
refer to the braking resistor documentation for
detailed wiring diagrams.

Selecting Braking Resistors for External Braking Units

200V Class Inverters – The following tables
specify the braking options for 200V class
SJ100 inverters and the braking torque for
each option. You can connect a single braking
unit to the inverter, or two braking units for
additional stopping torque.

Inverter

JRB x (2) parallel

+

RB

400V Class

Dynamic Braking Resistor Selection

JRB Series

SRB/NSRB Series

HRB Series

SJ100

Model

Number

HP

Type &

(Qty)

Total

Ohms

Total

Watts

Max.

Duty

Cycle

(%)

Type &

(Qty)

Total

Ohms

Total

Watts

Max.

Duty

Cycle

(%)

Type &

(Qty)

Total

Ohms

Total

Watts

Max.

Duty

Cycle

(%)

004HFE/HFU

1/2

120–1

180

120

2.0

200–1

180

200

4.0

007HFE/HFU

1

120–1

180

120

2.0

200–1

180

200

4.0

015HFE/HFU

2

120–1

180

120

2.0

200–1

180

200

4.0

022HFE/HFU

3

120–2

100

120

1.5

200–2

100

200

3.0

030HFE

4

120–2

100

120

1.5

200–2

100

200

3.0

040HFE/HFU

5

120–2

100

120

1.5

200–2

100

200

3.0

055HFE/HFU

7.5

120–4

x (2) in

series

70

240

1.0

400–1

x (2) in

series

70

800

7.5

RB2

x (2) in

series

70

1200

10.0

075HFE/HFU

10

70

240

1.0

70

800

7.5

70

1200

10.0

Inverter

+

Braking

unit

Braking

unit

Advertising