External Signal for DC Braking

When the terminal [DB] is turned ON, the
DC braking feature is enabled. Set the follow-
ing parameters when the external DC braking
terminal [DB] is to be used:

• A_53 – DC braking delay time setting. The

range is 0.1 to 5.0 seconds.

• A_54 – DC braking force setting. The

range is 0 to 100%.

The scenarios to the right help show how DC
braking works in various situations.

1. Scenario 1 – The [FW] or [RV] terminal is

ON. When [DB] is ON, DC braking is
applied. When [DB] is OFF again, the
output frequency ramps to the prior level.

2. Scenario 2 – The Run command is applied

from the operator keypad. When the [DB]
terminal is ON, DC braking is applied.
When the [DB] terminal is OFF again, the
inverter output remains OFF.

3. Scenario 3 – The Run command is applied

from the operator keypad. When the [DB]
terminal is ON, DC braking is applied
after the delay time set by A_53 expires.
The motor is in a free-running (coasting)
condition. When the [DB] terminal is OFF
again, the inverter output remains OFF.

Output

frequency

[FW, RV]

[DB]

Scenario 1

Output

frequency

Run command

from operator

Scenario 2

Output

frequency

Scenario 3

[DB]

[DB]

Run command

(from operator)

1
0
1
0

t

t

t

delay

A 53

1
0

1
0

1
0

1
0

Option

Code

Terminal

Symbol

Function Name

Input

State

Description

07

DB

External DC Braking

ON

applies DC injection braking during deceleration

OFF

does not apply DC injection braking during
deceleration

Valid for inputs:

C_01, C_02, C_03, C_04,
C_05, C_06

Required settings:

A_53, A_54

Notes:

Do not use the [DB] input continuously or for a
long time when the DC braking force setting A_54
is high (depends on the motor application).

Do not use the [DB] feature for continuous or high
duty cycle as a holding brake. The [DB] input is
designed to improve stopping performance. Use a