Trip event and history monitoring – Hitachi SJ100 User Manual

Page 79

Advertising
background image

SJ100 Inverter

Conf

igur

ing

Dr
iv

e P

a

ra

m

e

ters

3–7

Trip Event and History Monitoring

The trip event and history monitoring feature lets you cycle through related information
using the keypad. See

“Monitoring Trip Events, History, & Conditions” on page 6–5

for

more details.

D_07 Scaled output frequency

monitor

Displays the output frequency
scaled by the constant in B_86.
Decimal point indicates range:
XX.XX 0.01 to 99.99
XXX.X 100.0 to 999.9
XXXX. 1000 to 9999
XXXX 10000 to 99990

Hz

/Hz01.0 0.00

“D” Function

Run

Mode

Edit

Range

and

Units

Func.

Code

Name /

SRW Display

Description

“D” Function

Run

Mode

Edit

Range

and

Units

Func.

Code

Name /

SRW Display

Description

D_08 Trip event monitor

Displays the current trip event.
information.

ERR1 EEPROM
ERR1 0.0Hz
ERR1 0.0A
ERR1 324.3Vdc
ERR1 RUN 000000H

D_09 Trip history monitor

Displays the previous two
events and their causes.

ERR2 EEPROM
ERR2 0.0Hz
ERR2 0.0A
ERR2 330.0Vdc
ERR2 RUN 000000H
ERR3 EEPROM
ERR3 0.0Hz
ERR3 0.0A
ERR3 328.7Vdc
ERR3 RUN 000000H

Cumulative operation
RUN time monitor

Displays total time the inverter
has been in RUN mode in
hours.

hours

RUN 000000H

Trip count

Displays cumulative number of
trip events.

trips

ERROR COUNT 009