SJ100 Inverter

Conf

igur

ing

Dr
iv

e P

a

ra

m

e

ters

3–17

Frequency-related Functions

Frequency Limits – Upper and lower
limits can be imposed on the inverter
output frequency. These limits will apply
regardless of the source of the speed refer-
ence. You can configure the lower
frequency limit to be greater than zero as
shown in the graph. The upper limit must
not exceed the rating of the motor or
capability of the machinery.

Upper

limit

Frequency command

Lower

limit

Settable

range

A 61

A 62

Output

frequency

0

“A” Function

Run

Mode

Edit

Defaults

Func.

Code

Name /

SRW Display

Description

–FE

(CE)

–FU

(UL)

–FR

(Jpn)

Units

A_61 Frequency upper limit

setting

Sets a limit on output
frequency less than the
maximum frequency (A_04)
Range is 0.5 to 360.0 Hz
0.0.. setting is disabled
>0.1 setting is enabled

0.0

0.0

0.0

Hz

LIMIT H 000.0Hz

A_62 Frequency lower limit

setting

Sets a limit on output
frequency greater than zero
Range is 0.5 to 360.0 Hz
0.0.. setting is disabled
>0.1 setting is enabled

0.0

0.0

0.0

Hz

LIMIT L 000.0Hz